Meng Tai Eyewear/Testing & Compliance

Testing & compliance

Tested here,
to the standard.

A spectrophotometer that measures a lens against EN ISO 12312-1, ANSI Z80.3 and AS/NZS 1067 in one pass, plus the mechanical rig that the frame has to survive.

Three standards, one measurement

Transmittance, UV400, filter category and color limits are measured on our own spectrophotometer, and the result is evaluated against the European, American and Australian/New Zealand sunglass standards simultaneously. A lens intended for three markets is not three tests.

This is a factory laboratory, not a certification body. It exists so that a problem is found here rather than in a third-party report after the container has shipped.

What it catches

The usual ones are a tint that drifts between lots and lands outside its category, a mirror coating that moves the transmittance, and a polarized axis that is a few degrees off after assembly. None of those are visible to the eye, all of them fail a standard, and all of them are cheap to find before packing and expensive to find after.

The lab

Eight more rigs.

ISO 12312-1 ANSI Z80.3 AS/NZS 1067
UV-VIS spectrophotometer showing a pass result against 3 eyewear standards
Spectrophotometer — transmittance, UV400, category and color limits, against 3 standards at once.
Optical lens measuring system

Optical

Resolution test chart

Resolution

High velocity impact tester

High Velocity Impact

Drop ball and high mass impact test rig

High Mass & Drop Ball

Durability and deformation tester

Deformation

Spring temple durability tester

Endurance

Steel wool abrasion tester

Abrasion

Polarized axis test rig on a head form

Polarized Axis

Certification and monitoring

ISO 9001:2015 — certified, valid to September 2029. The quality management system, audited by the certification body.

amfori BSCI — monitored as a supplier, valid to October 2028. Meng Tai is a monitored producer; amfori membership belongs to the brands and retailers who commission monitoring, and we do not describe ourselves as one. The audit report is available to customers on request.

Third-party testing — SGS, Intertek or ICS, arranged on customer request. Where a buyer needs an independent report rather than ours, that is the right way to get it.

GRS — not held. We run recycled grades today without it; Global Recycled Standard certification would follow a program that requires it and is large enough to carry the cost. See materials.

Customer audits are welcome at any time, announced or not.

Which standard applies to you

Sunglasses sold in the EU are assessed to EN ISO 12312-1 as personal protective equipment; the United States works to ANSI Z80.3; Australia and New Zealand to AS/NZS 1067. They are not interchangeable, and a lens can pass one category limit and miss another. Tell us the markets at quotation stage and the lens is specified against all of them from the start rather than retested later.

Tell us the markets.

We will specify the lens against every standard that applies before the first sample is cut.

Request a quotation